A straight beam ultrasonic probe is a 0° longitudinal-wave ultrasonic transducer used for non-destructive testing (NDT), ultrasonic flaw detection, and thickness-related inspection of metals and other suitable test materials.
This range is available in single-element and dual-element (TR / F10-F20 connector) configurations, across 0.5MHz, 1MHz, 2MHz, 4MHz, and 5MHz frequencies with 10mm, 12mm, and 20mm element sizes, giving NDT technicians a straightforward way to match a straight-beam transducer to their inspection procedure and instrument connector.
What Is a Straight Beam Ultrasonic Probe?
A straight beam ultrasonic probe (also called a 0-degree probe) transmits ultrasonic energy directly into a test material along a straight path, perpendicular to the contact surface. It is the standard probe configuration for detecting laminations, internal discontinuities, and material loss, and for general Ultrasonic Thickness-related inspection. This probe range is offered in two element configurations:
Single-element (single crystal):Â
One piezoelectric element performs both transmit and receive functions, a simple, cost-effective configuration for general straight-beam inspection.
Dual-element (TR / F10, F20 connector):Â
Two separate elements handle transmit and receive independently, which can assist near-surface resolution and is commonly used with F10/F20-style dual-Lemo00 ultrasonic flaw detectors.
Technical Specifications
| Specification | Details |
| Product Type | Straight Beam (0°) Ultrasonic Probe / Transducer |
| Element Configuration | Single element or dual element (TR) |
| Available Frequencies | 0.5MHz, 1MHz, 2MHz, 4MHz, 5MHz |
| Available Element Sizes | 10mm, 12mm, 20mm |
| Connector – Single Element | Lemo00 (C5) for Φ8–Φ20 sizes |
| Connector – Dual Element | F10 (10mm/12mm sizes) or F20 (20mm size), dual Lemo00-style |
| Manufacturing Standard | EN12668-2 |
| Instrument Compatibility | Standard ultrasonic flaw detectors and thickness gauges using Lemo00/F10/F20-style probe connections |
| Condition | New |
| Typical Applications | NDT flaw detection, weld and material inspection, thickness-related testing |
Available Configurations
Single-Element Straight Beam Probes
- 0.5MHz, 10mm
- 1MHz, 10mm
- 2MHz, 10mm
- 4MHz, 10mm
- 0.5MHz, 12mm
- 1MHz, 12mm
- 0.5MHz, 20mm
- 1MHz, 20mm
- 2MHz, 20mm
- 4MHz, 20mm
Dual-Element (TR) Straight Beam Probes
- F10 connector – 1MHz, 10mm
- F10 connector – 2MHz, 10mm
- F10 connector – 4MHz, 10mm
- F10 connector – 5MHz, 10mm
- F10 connector – 4MHz, 12mm
- F20 connector – 4MHz, 20mm
Key Features & Benefits
- Wide frequency range 0.5MHz to 5MHz covers coarse-grained materials through to finer-resolution inspection needs.
- Single or dual element choice select single-crystal for general straight-beam work or dual-element (TR) for improved near-surface performance.
- Multiple element sizes 10mm, 12mm, and 20mm options suit different contact-area and coupling requirements.
- Lemo00 / F10 / F20 connectors compatible with common ultrasonic flaw detectors and thickness gauges using these probe connections.
- Built to EN12668-2 manufactured in line with this ultrasonic probe performance standard.
- Supplied new every probe ships new.
Typical Applications
- Ultrasonic flaw detection (NDT/UT)
- Metal crack and porosity inspection
- Internal discontinuity and lamination detection
- Weld and fabrication inspection
- Material condition and thickness-related assessment
- General-purpose straight-beam ultrasonic testing
How to Choose the Right Probe
Choose by Element Configuration
Choose a single-element probe for straightforward straight-beam inspection where one transmit/receive crystal is sufficient. Choose a dual-element (TR / F10-F20) probe when your procedure calls for separate transmit and receive elements, which can help resolve indications close to the entry surface.
Choose by Frequency
- 0.5MHz–1MHz: lower frequencies for coarse-grained or attenuative materials and greater penetration depth.
- 2MHz: a general-purpose mid-range frequency for a wide range of inspection tasks.
- 4MHz–5MHz: higher frequencies for finer resolution on suitable fine-grained materials.
Choose by Element Size and Connector
Confirm the required element size (10mm, 12mm, or 20mm) and check that the connector – Lemo00 for single-element probes, or F10/F20 for dual-element probes – matches your ultrasonic flaw detector or thickness gauge before ordering.
Frequently Asked Questions
What is a straight beam ultrasonic probe used for?
A straight beam ultrasonic probe introduces ultrasonic energy directly into a test material at 0 degrees. It is used for NDT flaw detection, internal discontinuity inspection, and thickness-related testing of metals and other suitable materials.
What is the difference between single-element and dual-element (TR) probes?
A single-element probe uses one crystal for both transmitting and receiving the ultrasonic pulse. A dual-element (TR) probe uses two separate crystals – one to transmit and one to receive which is commonly used with F10/F20-style connectors and can assist with near-surface resolution.
What frequencies are available?
This probe range is available in 0.5MHz, 1MHz, 2MHz, 4MHz, and 5MHz configurations.
What element sizes are available?
Element sizes of 10mm, 12mm, and 20mm are available, depending on the frequency and element configuration selected.
What connector does this probe use?
Single-element probes use a Lemo00 (C5) connector. Dual-element probes use an F10 connector (10mm/12mm sizes) or an F20 connector (20mm size).
Will this probe work with my ultrasonic flaw detector?
Check that your instrument accepts a Lemo00, F10, or F20-style probe connection (matching the variant you select) before ordering. If you need a different connector standard, see our BNC to Lemo S00 ultrasonic cable for connector conversion.
Is this probe Suitable For weld inspection?
Yes. Straight beam probes are commonly used alongside angle beam probes, such as our NDT ultrasonic angle beam probe, as part of a complete weld and material inspection procedure.
What condition is this probe supplied in?
Every probe is supplied new.
Related Equipment
Complete your ultrasonic testing kit with these related products:
- Dual Crystal Straight Probes 0 Degree Ultrasonic TR Probe 2MHz/4MHz/5MHz
- NDT UT Ultrasonic Angle Beam Probe 8x9mm 2MHz/4MHz
- Mitech 4MHz Angle Beam Probe Transducer Set (6-Piece)
- BNC to Lemo S00 Ultrasonic Flaw Detector Cable
- GE DA501EN 5MHz 12.5mm Ultrasonic Probe

















Reviews