The Tornatech ViZiTouch is the colour touch screen operator interface (HMI) fitted to the door of Tornatech electric and diesel fire pump controllers. It combines an embedded microcomputer running software PLC logic, a pressure and event recorder, and a sealed membrane keypad, giving fire services technicians a single panel to monitor system pressure, start or stop the pump, review alarms and adjust controller settings. This listing is for one used ViZiTouch operator interface module with its mounting brackets and screws.
What Is the Tornatech ViZiTouch Operator Interface?
The ViZiTouch is the “brain and face” of a Tornatech fire pump controller. It reads the pressure transducer, manages automatic and manual starting sequences, records pressure curves and events, and displays everything on a 4.2″ colour touch screen with intuitive graphics. It is used across Tornatech’s full-service electric fire pump controller range (such as models GPA, GPY, GPP, GPR, GPW and GPS) and the diesel engine fire pump controller model GPD, all built to NFPA 20.
Key Features of the ViZiTouch Fire Pump Controller HMI
- Colour touch screen display : 4.2″ colour HMI screen with graphical menus for pressure, alarms, settings and service.
- Embedded microcomputer with software PLC logic : Handles automatic start on pressure drop, sequential start timers, minimum run timers and weekly test scheduling.
- Pressure and event recorder : Stores pressure curves, event logs (alarms, resets, power events) and history statistics such as first power-up, first start-up and total on-time.
- Expandable storage : SD card slot on the rear housing for extended data storage.
- Upgradable, multi-language software : Firmware can be updated in the field; password-protected menus prevent unauthorised setting changes.
- Membrane keypad : Home, Alarms, Settings and Back keys, 5-way navigation pad, a green Start push button and a red Stop push button.
- Communication ports : USB port, RJ45 Ethernet port (TCP/IP), DB9 RS485 port and a DB25 port for the controller I/O card.
- 24VDC power input : Two-pin green plug-in terminal on the rear panel.
- Field wiring terminal strip : Multi-pin green pluggable terminal block for controller I/O connections.
- Hinged clear protective cover : Transparent flip-up cover with red gasket seal and latches to protect the screen and keypad from dust and accidental operation.
Benefits for Fire Protection Contractors and Facility Managers
- Restore a fire pump controller with a faulty or damaged display while keeping the existing cabinet and wiring.
- Keep a spare ViZiTouch HMI on the shelf to cut downtime on critical fire pump installations.
- Access stored pressure and event history to support routine testing and inspection records.
- Genuine Tornatech hardware – the Tornatech and ViZiTouch branding is printed on the housing.
Tornatech ViZiTouch Specifications
| Specification | Details |
|---|---|
| Brand | Tornatech |
| Model | ViZiTouch (ViZi Touch) Operator Interface |
| Product Type | Fire pump controller HMI / operator interface module |
| Display | 4.2″ colour touch screen (HMI technology) |
| Processing | Embedded microcomputer with software PLC logic |
| Data Recording | Pressure and event recorder, history and statistics |
| Storage | Expandable (SD card slot) |
| Keypad | Membrane keys: Home, Alarms, Settings, Back, 5-way navigation, Start (green), Stop (red) |
| Ports | USB, RJ45 Ethernet, DB9 RS485, DB25 I/O card port |
| Power Input | 24VDC (2-pin plug-in terminal) |
| Software | Upgradable, multi-language, password protected |
| Front Cover | Hinged clear protective cover with gasket seal |
| Used In | Tornatech fire pump controllers built to NFPA 20 (e.g. GPx electric series, GPD diesel) |
| Included | 1 x ViZiTouch operator interface, brackets and screws |
| Condition | Used |
Applications
- Electric motor-driven fire pump controllers in commercial and high-rise buildings
- Diesel engine fire pump controllers in pump rooms, warehouses and industrial sites
- Fire sprinkler and hydrant booster pump systems
- Mining, oil and gas, and infrastructure fire water systems
- Fire services maintenance contractors carrying critical spares
Installation Notes
The ViZiTouch mounts to the controller door using the supplied brackets and screws, then connects to the controller’s I/O card and 24VDC supply. Controller settings (pressure set points, timers, transducer range) must be configured to suit your fire pump installation. Installation and commissioning should be carried out by a qualified fire protection technician in line with AS 2941, NFPA 20 and the controller manufacturer’s instructions.
Frequently Asked Questions
What is the Tornatech ViZiTouch?
The ViZiTouch is Tornatech’s colour touch screen operator interface for fire pump controllers. It monitors system pressure, controls pump starting and stopping, and records pressure curves and events.
Which Tornatech fire pump controllers use the ViZiTouch?
The ViZiTouch is used on Tornatech full-service electric fire pump controllers (GPx series such as GPA, GPY, GPP, GPR, GPW and GPS) and the GPD diesel engine fire pump controller. Check the interface fitted to your controller before ordering.
Is this a complete fire pump controller?
No. This listing is for the ViZiTouch operator interface (HMI) module only, with brackets and screws. The controller cabinet, I/O card, contactors and pressure transducer are not included.
What ports does the ViZiTouch have?
The unit shown has a USB port, an RJ45 Ethernet port, a DB9 RS485 port, a DB25 I/O card port, an SD card slot, a 24VDC power input and a pluggable field terminal strip.
Does the ViZiTouch record pressure data?
Yes. It includes a built-in pressure and event recorder that stores pressure curves, alarm events and history statistics for testing and inspection records.
What condition is this unit in?
This ViZiTouch is used and may show cosmetic signs of previous service. You will receive exactly the item shown in the photos.
Related Equipment
- T-Link 4GX Industrial Cellular Router 288-0000 remote monitoring of pump room alarms and data.
- 30m Ultrasonic Liquid Level Sensor (4-20mA & RS485) monitor fire water storage tank levels.
- Fluke 750P30 High Pressure Module verify fire pump pressure transducer readings.
- M12 X-Coded to RJ45 Industrial Ethernet Cable rugged network cabling for controller connectivity.
- M12 to RJ45 Shielded Ethernet Cable IP67 shielded cabling for plant-room networks.









Reviews
There are no reviews yet.