The QDY80A 80GHz radar level sensor is a non-contact FMCW radar level transmitter that measures the distance to a liquid or solid surface using a 76–81GHz millimetre-wave signal and converts it into a level, distance or percentage reading with ±1mm accuracy. It mounts through a standard G1.5″ thread, runs on 24VDC, and is available with either a 4-20mA + HART or a 4-20mA + RS485 (Modbus) output in six measuring ranges from 0–3m to 0–25m.
With a narrow 8° emission angle, an 8cm dead zone and a built-in dot-matrix display, this 80G radar level meter is built for wastewater wet wells, sumps, process tanks, reservoirs and open channels where floats, probes or ultrasonic sensors struggle with foam, vapour, condensation or agitation.
Key Benefits of the QDY80A 80G Radar Level Transmitter
- ±1mm measurement accuracy from a 76–81GHz FMCW radar with a 5GHz operating bandwidth
- Non-contact measurement not affected by the density, concentration or other physical properties of the medium
- Narrow 8° beam (lens antenna) that reduces false echoes from tank walls, ladders and fittings
- Small 8cm dead zone so more of the tank height is usable
- Two output options 4-20mA with HART protocol, or 4-20mA with RS485 Modbus
- Integrated design with no moving parts no mechanical wear and a long service life
- SS304 stainless steel antenna and cast aluminium housing for corrosion and impact resistance
- IP67 protection for outdoor and wash-down installations
- Built-in filtering function to eliminate false interference echoes
Features of This Non-Contact Radar Level Meter
Millimetre-Wave RF Chip for Higher Resolution
The QDY80A uses an integrated millimetre-wave RF chip. Its compact RF architecture delivers a higher signal-to-noise ratio, smaller blind spots and a 5GHz operating bandwidth, giving higher measurement resolution and accuracy. The sensor can detect level movements as small as a few millimetres.
Time-of-Flight Radar Measuring Principle
The radar level gauge emits an electromagnetic wave that reflects off the surface of the measured material and is received back by the antenna. Because electromagnetic waves travel through vacuum and are not affected by atmosphere, volatile fog or vapour space, readings stay stable in conditions that upset ultrasonic level sensors.
Local Display and Push-Button Programming
- 128 × 64 dot-matrix display with four buttons for on-site setup
- Configuration through PC (upper computer) setup software
- Selectable fault output: 3.8mA, 4mA, 20mA, 21mA or hold
- Measurement interval of max. 100ms
Flexible Wiring for PLC, SCADA and IoT
The 4-20mA RS485 version provides a separate 4-20mA analogue pair plus RS485 (A/B) terminals, convenient for connecting to a PC for debugging or to RS485 field networks. The 4-20mA HART version carries digital HART communication on the current loop, so it can be configured and read with HART communicators and HART-enabled control systems.
Robust Process Connection
The G1.5″ threaded process connection with SS304 antenna suits standard tank couplings and bosses for quick, economical installation. The electronics head has an M20 × 1.5 cable inlet and accepts AWG18 or 0.75mm² cable.
Setup Menu and Configuration Functions
The on-board menu (Basic Settings, Advanced Settings, Service and Display) is operated with the [OK], [BK], up and down keys. Display modes include Run, Echo curve, History curve, Setup and Input.
Basic Settings
- High/low adjustment : Sets the full and empty points that map the level to the 4-20mA output
- Range and blind zone : Blind zone adjustable from 0 to 0.5m; echoes inside it are ignored
- Damping time : Higher values give a steadier output and stronger interference resistance
- Medium and container type : Presets for stable output, fast-changing levels or field testing
Advanced Settings and Service
- False echo learning learns fixed obstructions in the vessel and builds a noise threshold curve
- Distance offset and output direction selection
- Modbus bus address for connecting two or more instruments on one RS485 line
- Current simulation for loop checks (factory calibrated) and a selectable loss-of-echo fault current
- Echo lock, search window, first- and second-level filtering, response rate and threshold for fine-tuning in difficult tanks (higher response rate suits solids, lower suits liquids)
Display Options
- Shows level, height (distance) or percentage; default unit is metres
- Menu languages: English, Chinese and Korean
- Adjustable LCD contrast; echo curve shows signal strength (around 220dB on a good reflector, below 70dB indicates a weak echo)
QDY80A Radar Level Sensor Specifications
| Specification | Details |
| Model Number | QDY80A |
| Product Type | 80GHz FMCW Radar Level Sensor / Transmitter |
| Frequency | 76–81GHz (5GHz operating bandwidth) |
| Measuring Range Options | 0–3m, 0–5m, 0–10m, 0–15m, 0–20m, 0–25m |
| Accuracy | ±1mm |
| Dead Zone | 8cm |
| Emission Angle | 8° |
| Output Options | 4-20mA + HART, or 4-20mA + RS485 (Modbus) |
| Fault Output | 3.8mA, 4mA, 20mA, 21mA, hold |
| Power Supply | 24VDC (typical); 12–28VDC range |
| Measurement Interval | Max. 100ms |
| Dielectric Constant | ≥ 2 |
| Medium Temperature | -30°C to +100°C |
| Process Pressure | 0.1–1MPa |
| Ambient Conditions | -40°C to +85°C, humidity ≤ 95% RH |
| Process Connection | G1.5″ thread |
| Antenna Material | SS304 stainless steel |
| Housing Material | Cast aluminium |
| Display / Programming | 128 × 64 dot-matrix display, 4 buttons; PC setup software |
| Cable Inlet | M20 × 1.5 |
| Recommended Cable | AWG18 or 0.75mm² |
| Protection Rating | IP67 |
| Explosion-Proof Grade (manufacturer data) | Ex dia IIC T6 |
| Application | Liquid and solid level measurement |
| Certification | CE |
| Condition | New |
Available Variants : Output and Measuring Range
| Output | Measuring Range | Typical Use |
| 4-20mA HART / 4-20mA RS485 | 0–3m | Small tanks, IBCs, dosing tanks, pits |
| 4-20mA HART / 4-20mA RS485 | 0–5m | Wastewater wet wells, sumps, buffer tanks |
| 4-20mA HART / 4-20mA RS485 | 0–10m | Process vessels, water storage tanks |
| 4-20mA HART / 4-20mA RS485 | 0–15m | Large storage tanks, channels, culverts |
| 4-20mA HART / 4-20mA RS485 | 0–20m | Bridge-mounted river gauging, deep wells |
| 4-20mA HART / 4-20mA RS485 | 0–25m | Reservoirs, dams and tall vessels |
Choose a range that exceeds the maximum distance from the antenna to the lowest expected level.
Applications of the 80GHz Radar Liquid Level Sensor
- Wastewater and sewage treatment wet wells, lift stations, clarifiers and sludge tanks
- Water supply reservoirs, storage tanks, deep wells and irrigation channels
- River, creek and flood-warning level stations (bracket mounting)
- Chemical, food and beverage process tanks with agitation or condensation
- Feed, grain and powder silos (solid level measurement)
- Pump control and level alarms when paired with a level display/controller
- PLC, SCADA and IoT telemetry via 4-20mA, HART or Modbus RS485
80GHz vs 26GHz Radar Level Gauges
| Feature | 80GHz (QDY80A) | Typical 26GHz Radar |
| Dead Zone | 8cm | Approx. 30cm |
| Precision | ±1mm | Approx. ±5mm |
| Working Conditions | Steam, agitation, volatilisation, bubbles, dust, complex conditions | Normal working conditions |
Installation Guidelines
- Mount the sensor so the beam is vertical to the measured surface
- Keep the beam path clear of interference such as ladders, stairs and steps
- Position the antenna so the beam avoids the feed inlet stream
- Install at least 200mm (7.87″) from the vessel wall to avoid incorrect readings
- In conical-bottom tanks, angle the beam towards the tank outlet so low levels read correctly
- Mounting options: screw (thread) mounting as standard; bracket mounting suits rivers, reservoirs and deep wells
Frequently Asked Questions
What is the QDY80A 80GHz radar level sensor?
The QDY80A is a non-contact FMCW radar level transmitter operating at 76–81GHz. It measures liquid or solid level with ±1mm accuracy and outputs 4-20mA with HART or 4-20mA with RS485.
What is the difference between the 4-20mA HART and 4-20mA RS485 versions?
Both provide a 4-20mA analogue level signal. The HART version adds HART digital communication on the current loop, while the RS485 version adds separate RS485 (Modbus) terminals for digital networking and PC debugging.
Which measuring ranges are available?
Six ranges are offered: 0–3m, 0–5m, 0–10m, 0–15m, 0–20m and 0–25m.
Is this radar level sensor suitable for wastewater?
Yes. Non-contact 80GHz radar is not affected by foam, vapour, condensation or the density of the medium, making it well suited to wastewater wet wells, sumps and treatment tanks.
What power supply does the QDY80A need?
It is supplied for 24VDC operation (12–28VDC range).
Does it have a local display?
Yes. A 128 × 64 dot-matrix display with four buttons allows on-site configuration, and PC setup software can also be used.
What is the process connection?
The standard process connection is a G1.5″ thread with an SS304 stainless steel antenna.
What is included?
One QDY80A 80GHz radar level sensor in your selected output and measuring range, supplied new.







Reviews