The 80GHz radar level meter is a non-contact FMCW (frequency-modulated continuous wave) level transmitter that sends a 76–81GHz millimetre-wave signal to the surface of a liquid or bulk solid and calculates level from the returning echo with ±1mm accuracy. It is offered in nine process connections – G1.5″ thread, G3.5″ large-lens thread, DN50 anti-corrosion flange, DN80–DN150 high-temperature flanges and DN80/DN100 universal (angle-adjustable) flanges with measuring ranges of 0–30m or 0–60m, a 24VDC supply and a 4-20mA output with HART and RS485 capability.
Because nothing touches the medium, this 80G radar level gauge is a dependable choice for mixing tanks, high-temperature vessels, steam and foam, acid and alkali liquids, dusty silos, rivers and reservoirs where floats, probes and ultrasonic sensors struggle.
Key Benefits of the 80GHz Radar Level Transmitter
- ±1mm measuring accuracy from high-frequency 76–81GHz FMCW radar
- Narrow, focused beam fewer false echoes from tank walls, ladders, heating coils and agitator blades
- Smaller blind zone and higher signal-to-noise ratio thanks to a compact millimetre-wave RF chip
- Nine mounting versions thread, large-lens thread, anti-corrosion flange, high-temperature flange and universal flange
- Up to 200°C and 2.5MPa on the high-temperature flange versions
- Works through steam, foam, vapour, condensation and dust
- Industrial outputs 2-wire 4-20mA as standard, with a 4-wire 4-20mA + HART + RS485 build for PLC, DCS and SCADA integration
- Local LCD and four-key keypad for commissioning without a laptop
- Explosion-proof style housing with metal waterproof cable gland and external earth terminal
- Automatically calibrated before dispatch ready to set up on arrival
Features of This 80G Radar Level Gauge
Millimetre-Wave RF Chip
The integrated millimetre-wave RF chip gives a more compact RF structure, a higher signal-to-noise ratio and smaller blind zones than 6GHz or 26GHz radar. The tight 80GHz beam reaches the product surface through narrow nozzles and past internal fittings.
Intelligent Echo Compensation
- Real-time echo curve shown on the display for quick set-up and fault-finding
- Intelligent temperature compensation to reduce measurement error
- Effective shielding of false echoes and intelligent clutter recognition, so agitator interference is ignored
Multi-Data LCD Display
The display behind the screw-on window shows material level (m), empty height (m), percentage (%), loop current (mA) and sensor temperature. Using the ESC, +, ▶ and OK keys you can set high and low level calibration points, choose the medium type (liquid or solid) and view the echo curve.
Waterproof, Explosion-Proof Style Electrical Interface
The electronics head uses an explosion-proof style metal waterproof cable connector with resistance to impact, ageing and high temperature, plus a sealed blanking plug and an external earth terminal.
Universal Flange With Air Purge for Solids and Dust
The universal flange versions allow the antenna angle to be adjusted so the beam can be aimed at the lowest point of a cone or stockpile. An air-purge (blow-down) port keeps the lens clear of dust, making these models suited to powders, ash, cement, grain and granular solids.
Lens Antenna Options
The 304 stainless steel process connections carry a PTFE lens antenna. The G1.5″ thread suits standard tank bosses, while the G3.5″ large lens delivers a more concentrated beam for the extended 0–60m range.
80GHz Radar Level Meter Specifications
| Specification | Details |
|---|---|
| Product Type | 80GHz FMCW non-contact radar level meter / transmitter |
| Model | RS series 80G radar level meter |
| Frequency Range | 76–81GHz |
| Measuring Range | 0–30m (G1.5″ thread and all flange versions); 0–60m (G3.5″ large-lens thread) |
| Accuracy | ±1mm |
| Output | 2-wire 4-20mA (standard); 4-wire 4-20mA + HART + RS485 (specify when ordering) |
| Power Supply | 24VDC (standard); 220VAC option available |
| Process Temperature | -30 to +100°C (thread, large lens, anti-corrosion and universal flange); -30 to +200°C (high-temperature flange) |
| Process Pressure | -0.1 to 1MPa (thread, large lens and universal flange); -0.1 to 2.5MPa (high-temperature flange) |
| Process Connections | G1.5″ thread, G3.5″ thread, DN50 flange, DN80 / DN100 / DN125 / DN150 flange, DN80 / DN100 universal flange |
| Wetted Materials | 304 stainless steel / PTFE |
| Suitable Media | Liquids, agitated surfaces, vapour, condensation, steam, foam, acid and alkali liquids; solids, dust and powder (universal flange) |
| Display & Keypad | LCD with ESC / + / ▶ / OK keys; level, distance, %, mA, temperature and echo curve |
| Electrical Connection | Metal waterproof cable gland, blanking plug, external earth terminal |
| Certification | CE |
| Condition | New |
Radar Level Meter Variants : Choose Your Connection
| Variant | Range | Temperature / Pressure | Best For |
|---|---|---|---|
| 0–30m G1.5″ Thread | 0–30m | -30 to 100°C / -0.1 to 1MPa | Water tanks, wet wells, general liquid storage |
| 0–60m G3.5″ Large-Lens Thread | 0–60m | -30 to 100°C / -0.1 to 1MPa | Rivers, reservoirs, dams and tall tanks |
| 0–30m DN50 Anti-Corrosion Flange | 0–30m | -30 to 100°C | Acid and alkali liquids, mixing and condensation |
| 0–30m DN80 High-Temperature Flange | 0–30m | -30 to 200°C / -0.1 to 2.5MPa | Hot, corrosive or steaming process vessels |
| 0–30m DN100 High-Temperature Flange | 0–30m | -30 to 200°C / -0.1 to 2.5MPa | Reactors, boilers and hot storage tanks |
| 0–30m DN125 High-Temperature Flange | 0–30m | -30 to 200°C / -0.1 to 2.5MPa | Larger nozzles on hot process vessels |
| 0–30m DN150 High-Temperature Flange | 0–30m | -30 to 200°C / -0.1 to 2.5MPa | Large nozzles, foam and heavy vapour |
| 0–30m DN80 Universal Flange | 0–30m | -30 to 100°C / -0.1 to 1MPa | Silos, dust, powder and granular solids |
| 0–30m DN100 Universal Flange | 0–30m | -30 to 100°C / -0.1 to 1MPa | Bulk solids, ash, cement and stockpiles |
Longer-range builds (70m and 120m), a 220VAC supply and a remote light-column display are available as factory options contact our team before ordering.
Applications for 80GHz Non-Contact Level Measurement
- Fire-service and domestic water storage tanks
- Industrial and sewage water tanks, wet wells and pump stations
- River, creek, reservoir and dam water level monitoring
- Mixing tanks and agitated vessels
- High-temperature, steam and foam process tanks
- Strong acid and alkali chemical storage
- Silos and hoppers for powder, ash, mud, cement and grain
- Remote telemetry, PLC and SCADA level reporting via 4-20mA, HART or RS485 Modbus
Why Choose 80GHz Radar Over Ultrasonic or 26GHz Radar?
- Narrower beam angle fewer reflections from obstructions
- Not affected by temperature, vapour, wind or dust the way ultrasonic sound waves are
- Smaller antenna fits a G1.5″ thread or compact flange
- Smaller blind zone more usable tank capacity near the top
Installation Tips
- Mount the antenna perpendicular to the liquid surface and away from the filling stream
- For solids, use a universal flange and tilt the antenna towards the outlet cone
- Connect clean, dry air to the purge port in dusty applications
- Earth the housing through the external earth terminal
- Use shielded twisted-pair cable for 4-20mA/HART and RS485 runs
- Set the empty and full calibration points with the keypad after mounting
Frequently Asked Questions
What is an 80GHz radar level meter?
It is a non-contact level transmitter that emits a 76–81GHz FMCW radar signal and calculates the distance to the product surface from the reflected echo, giving level readings with ±1mm accuracy.
Which mounting version should I choose?
Choose the G1.5″ thread for general liquids, the G3.5″ large lens for ranges up to 60m, the DN50 anti-corrosion flange for acids and alkalis, a high-temperature flange for hot or pressurised vessels up to 200°C and 2.5MPa, and a universal flange for solids, dust and powders.
What outputs are available?
The standard unit has a 2-wire 4-20mA output. A 4-wire version with 4-20mA, HART and RS485 is available for full digital integration – specify it when ordering.
Can it measure through steam, foam and dust?
Yes. The 80GHz beam is designed for steam, foam, vapour, condensation and agitated surfaces, and the universal flange versions include an air-purge port for dusty solids.
What power supply does it need?
24VDC is standard. A 220VAC supply option is available on request.
Is it certified for hazardous areas?
The meter has an explosion-proof style housing and carries CE certification. If your site requires a specific hazardous-area (Ex) certificate, please contact us to confirm before ordering.
Can I set it up without software?
Yes. The LCD and four-key keypad let you set high and low calibration points, select liquid or solid medium and view the echo curve directly on the meter.
What is included?
One 80GHz radar level meter with the process connection and measuring range you select, supplied new.
















Reviews