The Topcon total station side cover is a new, moulded plastic replacement housing plate that encloses the left or right side of the instrument standard on Topcon GTS-1002, GTS-2002, GTS-332N, GTS-102N, ES-602, GM-52, OS-201, Cygnus 2LS and KS-202 total stations.
Each cover is shaped to match one specific model and side, so the screw points, battery/port openings and display window line up with the original instrument body. Covers are sold individually choose your model and side (Cover A or Cover B) from the options above.
Why Replace a Cracked or Missing Total Station Side Cover?
The side covers of a total station protect the internal circuit boards, keyboard flex cables, battery contacts and optical-drive electronics from dust, rain and knocks. A cracked, broken or lost cover exposes those components to the site environment and can lead to moisture ingress, dust contamination and costly board failures. Replacing just the damaged side housing restores protection at a fraction of the cost of a full repair or a new instrument.
- Restores weather and dust protection for internal electronics and wiring
- Returns a clean, professional look to a well-used instrument before resale or hire
- Cost-effective repair part – replace one plate instead of the whole standard
- Keeps the instrument in the field and reduces workshop downtime
Key Features of This Topcon Replacement Side Housing
- Model-specific moulding: each variant follows the profile, fixing points and openings of the listed Topcon model.
- Durable engineering plastic: lightweight, impact- and wear-resistant shell suited to daily field use.
- Left and right options: Cover A and Cover B versions are listed separately for most models so you only buy the side you need.
- Original-style colours: Topcon yellow, grey and two-tone finishes to match the rest of the instrument.
- Straightforward fitting: designed as a direct swap using the instrument’s existing screws and internal components.
- Optional logo badge: a round green emblem badge is also available to finish off a refurbished unit.
Suitable Topcon Total Station Models & Variant Guide
Use this table to match your instrument to the correct side cover variant. Each variant photo shows the front (outside) and back (inside) of the cover.
| Variant | Fits Instrument | Colour |
|---|---|---|
| GTS-1002 / OS-201 – Cover A | Topcon GTS-1002, OS-201 series | Yellow |
| GTS-1002 / OS-201 – Cover B | Topcon GTS-1002, OS-201 series | Yellow |
| GTS-2002 – Cover A | Topcon GTS-2002 series | Yellow |
| GTS-2002 / GM – Cover B | Topcon GTS-2002 and GM series | Yellow |
| GM-52 – Cover A | Topcon GM-52 / GM series | Yellow |
| GTS-332N – Cover A | Topcon GTS-332N / GTS-330N series | Yellow |
| GTS-332N – Cover B | Topcon GTS-332N / GTS-330N series | Yellow |
| GTS-102N – Cover A | Topcon GTS-102N / GTS-100N series | Grey |
| GTS-102N – Cover B | Topcon GTS-102N / GTS-100N series | Grey |
| ES-602 – Cover A | Topcon ES-602 / ES series | Grey |
| ES-602 – Cover B | Topcon ES-602 / ES series | Grey |
| 2LS – Cover A | Cygnus 2LS | Orange / Grey |
| 2LS – Cover B | Cygnus 2LS | Grey / Orange |
| KS-202 (TKS-202) – Cover A | KS-202 / KS-202N | White / Grey |
| KS-202 (TKS-202) – Cover B | KS-202 | Dark Grey |
| KS-202N (TKS-202N) – Cover B | KS-202N | Dark Grey |
| Logo Badge | Round emblem badge for instrument housing | Green |
Technical Specifications
| Specification | Details |
|---|---|
| Product Type | Total station side cover / side housing plate (left or right) |
| Model Number | PJ-CG-TPK |
| Compatible Brand | Topcon (and Topcon-built Cygnus 2LS / KS-202 series) |
| Compatible Models | GTS-1002, OS-201, GTS-2002, GM-52 / GM, GTS-332N, GTS-102N, ES-602, 2LS, KS-202, KS-202N |
| Material | Moulded engineering plastic |
| Options | Cover A / Cover B per model, plus logo badge |
| Quantity | 1 piece (per selected variant) |
| Package Size | 34 x 12 x 5 cm |
| Package Weight | 0.3 kg |
| Condition | New |
Common Use Cases
- Repairing a total station with a cracked, split or broken side housing after a tripod fall
- Replacing a missing side cover on a second-hand or ex-hire instrument
- Workshop refurbishment of Topcon GTS, ES, GM and OS series total stations
- Survey equipment service centres stocking common housing spare parts
- Cosmetic restoration before resale, hire or trade-in
Installation Tips
- Remove the battery and power off the instrument before opening the housing.
- Photograph the cable routing and any flex connectors before removing the old cover.
- Transfer any internal parts (keypads, seals, window glass, clips) from the old cover if they are not already fitted.
- Tighten fixing screws evenly and do not over-torque into the plastic bosses.
- Have the instrument’s calibration checked by a qualified technician after any internal repair work.
Frequently Asked Questions
What is a total station side cover?
It is the moulded plastic housing plate that closes the left or right side of the total station standard (the upright body that holds the telescope). It protects the internal electronics, cables and battery area from dust, water and impact.
Which Topcon total stations does this side cover fit?
Variants are available for Topcon GTS-1002, OS-201, GTS-2002, GM-52/GM series, GTS-332N, GTS-102N and ES-602, plus Cygnus 2LS and KS-202 / KS-202N instruments. Select the exact model in the options.
What is the difference between Cover A and Cover B?
Cover A and Cover B are the two opposite side housings (left and right) of the same instrument. Their shapes and openings differ, so compare the front and back photos of each variant with your existing cover to choose the correct side.
Is the price for one cover or a pair?
The price is for one cover. If you need both sides, add Cover A and Cover B to your cart separately.
Are internal parts such as the keypad, display or circuit boards included?
No. This is the plastic housing only. Keyboards, displays, cables and electronics are transferred from your existing instrument or purchased separately.
Is this a genuine Topcon part?
This is a new replacement housing made to match the listed Topcon models. Topcon, GTS, ES, GM and OS are used only to identify compatibility.
Can I fit the side cover myself?
Users with basic instrument-repair experience can usually fit it with standard small screwdrivers. If internal cables or boards must be moved, we recommend a qualified survey instrument technician.
What if my model is not listed?
Contact us with your instrument model and a photo of the old cover and we will confirm whether a matching side cover is available.
Related Topcon Total Station Parts
Complete your repair with these compatible spares:
The Topcon GTS/GPT total station keyboard display,
The Topcon ES-602 LCD display keyboard,
A yellow Topcon total station carrying case for GM-52, GTS-102N and GTS-332N,



















Reviews
There are no reviews yet.